Many more sizes and styles of heat
exchangers are available. Also available are heat
exchanger mounting brackets and Aeroflex pressure sensitive
insulation kits to seal against condensation on cold temperature
fluid applications. Consult the factory for details.
For radiant heating, domestic hot
water, snow melting, steam zoning, fuel pre-heating, general
shell & tube replacement.
•
All 316 Stainless Steel w/copper brazing
•
Maximum pressure 450 psi, temperature 365° F
•
UL Listed (US and Canada), CSA Approved
General Application
W/P no.
# plates
BTUH (1,000's)*
Pipe Connections
(Male NPT)
Approx. Dim & Weight
Radiant Heat
Heat Zoning
Domestic Hot Water
Snow Melting
Height
(in)
Width
(in)
Depth
(in)
Weight
(lbs)
H101-10
10
38
38
113
50
3/4"
8
2-7/8
1-1/2
2.8
H101-14
14
52
53
155
70
3/4"
8
2-7/8
1-7/8
3.2
H101-20
20
72
73
220
98
3/4"
8
2-7/8
2-3/8
3.8
H101-30
30
103
103
310
140
3/4"
8
2-7/8
3-5/16
5.0
H103-14
14
85
87
255
115
1"
6-3/4
4-7/8
1-7/8
4.5
H103-20
20
120
122
360
160
1"
6-3/4
4-7/8
2-3/8
5.3
H103-40
40
230
229
685
310
1"
6-3/4
4-7/8
4-1/4
7.8
H104-10
10
41
41
122
55
1"
13
4-7/8
1-1/2
6.2
H104-14
14
57
58
170
76
1"
13
4-7/8
1-7/8
7.2
H104-24
24
97
97
290
130
1"
13
4-7/8
2-3/4
9.8
H104-30
30
120
122
360
160
1"
13
4-7/8
3-5/16
11.4
H104-50
50
195
195
585
260
1"
13
4-7/8
5-1/4
16.6
Double Wall Vented - Protects against cross fluid
contamination
W/P no.
# plates
BTUH (1,000's)*
Pipe Connections
(Male NPT)
Approx. Dim & Weight
Radiant Heat
Heat Zoning
Domestic Hot Water
Snow Melting
Height
(in)
Width
(in)
Depth
(in)
Weight
(lbs)
H105-14
14
48
50
147
66
1"
20-7/8
4-7/8
1-7/8
11.8
H105-20
20
70
71
210
95
1"
20-7/8
4-7/8
2-3/8
15.0
H105-30
30
105
106
310
140
1"
20-7/8
4-7/8
3-5/16
20.3
H105-50
50
170
171
510
230
1"
20-7/8
4-7/8
5-1/4
31.0
H105-80
80
255
260
770
340
1"
20-7/8
4-7/8
8
47.0
H105-100
100
300
305
910
410
1"
20-7/8
4-7/8
10
57.5
High Capacity
W/P no.
# plates
BTUH (1,000's)*
Pipe Connections
(Male NPT)
Approx. Dim & Weight
Radiant Heat
Heat Zoning
Domestic Hot Water
Snow Melting
Height
(in)
Width
(in)
Depth
(in)
Weight
(lbs)
H107-20
20
265
270
785
350
2"
20-7/8
10-5/8
2-3/8
38.6
H107-24
24
310
320
940
420
2"
20-7/8
10-5/8
2-3/4
43.8
H107-30
30
380
390
1,150
520
2"
20-7/8
10-5/8
3-5/16
51.8
H107-40
40
500
508
1,500
670
2"
20-7/8
10-5/8
4-1/4
65.0
H107-50
50
590
602
1,785
800
2"
20-7/8
10-5/8
5-1/4
78.2
H107-60
60
685
680
2,000
920
2"
20-7/8
10-5/8
6-3/16
91.4
H107-100
100
885
885
2,600
1,200
2"
20-7/8
10-5/8
10
144.2
H107-120
120
930
925
2,750
1,270
2"
20-7/8
10-5/8
11-7/8
170.6
H107-150
150
960
950
2,850
1,330
2"
20-7/8
10-5/8
14-3/4
210.2
Hard Shell Foam Insulation Kits w/stainless clamps
# plates
Heat Exchanger Series
H101
H103
H104
H105
H107
10
H111-10
-
H114-10
-
-
14
H111-14
H113-14
H114-14
H115-14
-
20
H111-20
H113-20
-
H115-20
H117-20
24
-
-
H114-24
-
H117-24
30
H111-30
-
H114-30
H115-30
H117-30
40
-
H113-40
-
-
H117-40
50
-
-
H114-50
H115-50
H117-50
60
-
-
-
-
H117-60
80
-
-
-
H115-80
-
100
-
-
-
H115-100
H117-100
120
-
-
-
-
H117-120
150
-
-
-
-
H117-150
*Table 1 - Temperatures for BTUH ratings
shown
Heat Exchanger
Connected to
Heat Exchanger
Input Side (boiler)
Output Side (see note 1)
In
Out
In
Out
Radiant Heat
180°F
140°F
90°F
110°F
Heat Zoning
180°F
160°F
150°F
170°F
Domestic Hot
Water
180°F
120°F
60°F
120°F
Snow Melting
(see note 2)
180°F
140°F
100°F
130°F
Note 1: Output side pressure drop approx. 2
psi. Note 2: 40% Glycol in melt loop
Please Note The heat exchanger BTUH ratings shown
are very conservative, and were derived using familiar system
temperatures, flow rates, and pressure drops. For each heat
exchanger, the BTUH output can be greatly increased by choosing
different system design temperatures and increasing flow rates.